Fire Alarm Systems

Fire anywhere can be prevented if a functioning fire alarm system is installed. We render a wide pallet of Fire Alarm Systems to our esteemed clientele as per their specific requirements. We are happy to serve our buyers with the best of the lot every time they opt us for their security service partner. Our adept team is driven with the motto of offering satisfaction of the service rendered to each client and making them secured from fire outbursts at the initial stages.

 

We offer :-

  • Fire Panels
  • Fire Sensors

The broad spectrum of our products are as follows :-

Products

Fire Panels

AGNI XFP 1& 2 Loop

  • Third-party certificated to EN54 parts 2 and 4 by the LPCB
  • Two programmable inputs
  • Adjustable contamination levels
  • 999 event monitoring
  • An investigation delay period function
  • Adjustable contamination levels

AGNI ZFP 2-8 LOOP

  • Communication protocol Apollo XP95/Discovery
  • 2 or 4 loops in standard size box, 6 or 8 Loops in larger enclosure
  • Colour touch screen operation
  • Loopless panel repeaters
  • Loopless panel repeaters

AGNI Orion Series

  • Complies to IS 2189: 1999 and Tested by ERTL (N) & System Sensor.
  • 2 X 16 character backlit LCD display.
  • Lamp test feature.
  • Complete with integral power supply and battery charger for sealed lead acid battery.
  • NO/NC contacts for both fire and fault.
  • Switches to enable on board operation.
  • LCD and LED Indication for open, short circuit, Isolate, Fire in each zone.
  • Maximum nos. of Detectors in each zone is 25

AGNI Oriel Pro Series

  • Complies to IS 2189: 1999 and Tested by ERTL (N). and System Sensor.
  • 2 X 16 character backlit LCD display. (4 x 20 character, optional)
  • 256 Events logging facility with real time clock and keypad.
  • Central Monitoring with GSM Module.
  • Lamp test feature.
  • Complete with integral power supply and battery charger for sealed lead acid battery.
  • NO/NC contacts for both fire and fault.
  • Switches & Matrix Keypad 4×4 to enable on board operation.
  • LCD and LED Indication for open, short circuit, Isolate, Fire in each zone.
  • Maximum nos. of Detectors in each zone is 32.
  • Complete Address of individual detector in every zone

Fire Sensors

System Sensors

  • Unique ability to detect all four major elements of a fire
  • Highest nuisance alarm immunity
  • Advanced algorithms interpret and respond to the multiple inputs
  • Six levels of sensitivity
  • CO sensing for fastest response to slow-developing, smoldering fires
  • Fully integrated infrared sensing to support the fire alarm decision
  • Automatic drift compensation of smoke sensor and CO cell

Smoke Sensors

  • Low standby current
  • Compatible with 400 Series product
  • Two visible LEDs “blink” in standby and provide a 360° field viewing angle
  • Detector head plugs easily into base
  • Built-in test switch
  • Wide variety of mounting bases with built-in shorting spring

Smoke Sensors

  • Sleek, low-profile design
  • Analog communications
  • Low standby current
  • Rotary address switches
  • Superior EMI protection
  • Dual LEDs for 360° visibility

Fire Sensors

  • Unique ability to detect all four major elements of a fire
  • Separate CO detection signal
  • Highest nuisance alarm immunity
  • Automatic drift compensation of smoke sensor and CO cell
  • Uses only one address on the SLC
  • RealTest® CO testing capability
  • UL 268 and UL 2075 listed
  • Separates audible signal for fire or CO alarm when used with the B200S base (B200SCOA in Canada
  • CO cell end-of-life warning and fault

Carbon Monoxide Detectors

  • RealTest® enables a functional test using canned CO
  • Full compliance with UL 2075
  • A code-required trouble relay
  • Wiring supervision with SEMS terminals
  • A six-year end-of-life timer
  • 12/24 VDC
  • A low current draw of 20 mA in standby and 40 mA in alarm
  • Versatile mounting for wall and ceiling
  • Accurate and reliable electrochemical sensing technology
  • Optional CO-PLATE CO Detector Replacement Plate to upgrade
  • previously installed competitor detectors to the CO1224T

Beam Smoke Detectors

  • 16- to 328-foot protection range
  • Single-ended, reflective design
  • User-friendly alignment procedure
  • Six user selectable sensitivity levels
  • Optional integral NFPA 72 sensitivity test feature
  • Removable plug-in terminal blocks
  • Digital display for easy alignment
  • Built-in automatic gain control compensates for signal deterioration from dust build-up
  • Remote test station option
  • Paintable cover
  • Easiest alignment in the industry
  • Heater kits for transmitter/receiver and reflector option

CCTV Cameras & DVRs

We are one of the prominent dealers of CCTV Cameras and DVRs. All our products are obtained from trusted brands, who are renowned for their top class security systems. Our quality checking...

Read More

Attendance Systems

We render premium quality Attendance Systems that are easy to install in any commercial, industrial and residential places to monitor outsiders entering the premises. These are an apt tool...

Read More

Fire Alarm Systems

Fire anywhere can be prevented if a functioning fire alarm system is installed. We render a wide pallet of Fire Alarm Systems to our esteemed clientele as per their specific requirements...

Read More